METRO RAIL DESIGN CRITERIA SECTION 9 / SYSTEMS
DE304.09 9-108 Revision 4 : 05/09/12
Metro Baseline Re-Baseline: 04/29/10
Equipment shall be provided to allow recording and storing of new
announcements on local message repeater devices.
C. Provision shall be made for ROC Initiation and Selection of prerecorded
voice announcements from the ROC console.
D. The station EMP shall be able to broadcast an emergency evacuation
message from the local digital message repeater announcement device.
9.8.1.4 PA Zones
A. Separate zones with separate amplifying systems and speaker systems shall be
accessible individually or in combination. Passenger stations typically have one
to three zones covering; platform, mezzanine and ancillary areas. Shops and
yard areas have typically nine zones and ROC has typically four zones.
B. Zones for the ROC PA subsystem shall be uniform and provide an SPL of 70
dBA measured on axis of speakers at a point 4-feet above the floor and not less
than 60 dBA plus or minus 60 degrees off axis.
9.8.1.5 Standby Amplifiers
Hot-standby power amplifiers shall be provided on a one-for-two basis for each
power amplifier used in the PA subsystem installation. The hot-standby amplifiers
shall be switched to active use by the PA supervisory function.
9.8.1.6 Speaker By Local Microphones
Provision shall be made to reduce output level of speakers in close proximity of local
microphones to prevent acoustic feedback.
9.8.1.7 Noise-Operated Level Adjustments for Power Amplifiers