ERROR simply means loss of lock.
CRC error checking is not employed because some digital playback devices do not encode it properly, lead-
ing to false errors (eg the PSX-100 will not indicate an ERROR when receiving a CRC error flag).
MDM IN LEDs
Indicate which MDM channel pair is being monitored.
When two LEDs are lit (eg 1-2 and 3-4), the PSX-100 is applying Apogee Bit Splitting processing on the
MDM inputs to reconstruct a 44.1 kHz or 48 kHz bit-split signal.
When all four LEDs are lit, the PSX-100 is applying Apogee Bit Splitting processing on the MDM inputs to
reconstruct a 88.2kHz or 96kHz bit-split signal.
DIP Switches
The unit is shipped default from the factory with all the DIP switches in the OFF (down) position. The function-
ality is as follows:
DIP Function OFF (Down—default) ON (Up)
1 TDIF CLOCK TDIF clock is WC input TDIF clock is LRCK
See Note (1) below (clock signal in multipin
TASCAM connector)
2 OVER LED HOLD TIME infinite OVER LED hold
See Note (2) 2 second OVER LED hold
3 A/D INPUT POLARITY pin 2 hot pin 3 hot
4 NOMINAL OUTPUT LEVEL +4dBu (professional) 10 dBv (consumer)
5 NOMINAL INPUT LEVEL +4dBu (professional) 10 dBv (consumer)
6 OVER THRESHOLD
See OVER Threshold below
7 OVER THRESHOLD See OVER Threshold below
8 AES BIT-SPLITTING MODE ABS OFF on AES inputs Paqrat or ABS bit-split signals
always combined from two
AES inputs (not applicable at
88.2/96 kHz sampling)
9 SINGLE/DOUBLE WIRE Single-wire operation 88.2/96 Double-wire operation
10 WC OUTPUT RATE WC output is same as main rate WC output is 44.1/48 kHz
always, even when unit samples
at 88.2/96 kHz.
See Note (1)
NOTE 1: 88.2/96 kHz Word Clock operation and TDIF. DIP Switch 1 OFF selects Word Clock as the clock
source for TDIF. While operating at high sample rates (88.2/96 kHz), when the A/D SYNC is set to Word Clock
and the DA INPUT is TDIF, the PSX-100 expects a 44.1/48 kHz Word Clock. If the DA INPUT is NOT TDIF, then
the unit expects an 88.2/96 kHz Word Clock for AD SYNC to Word Clock. When using Word Clock to sync a
TDIF machine while bit-splitting at 88.2/96 kHz, be sure that DIP 10 is set to ON, as the TDIF device will be
recording at 44.1/48 kHz even though the converter is running at 88.2/96 kHz.
NOTE 2: Over Autoclear. When DIP Switch 2 is set to
OFF (infinite peak hold), AutoClear becomes active.
This feature clears the OVER LEDs when the level has
remained below about 50 dB for more than 30 sec-
onds and has then risen above 50 dB.
OVER Threshold
The PSX-100 allows the user to select the number of
consecutive OVERs required to illuminate the OVER indicators. When this threshold is set to 1 sample, every
sample that exceeds 0 dBFS (0 dB Full Scale digitally, this corresponds to all ones, ie the maximum level you
can convert) in level will trigger the OVER LEDs. When it is set to 4 samples, the OVER LEDs will only illuminate
when four consecutive samples are OVER 0 dBFS.